Salient Features
• Double-circuit type of limit switch, is widely used.
• Strong metal shell, swing angle max.+/- 95 deg.
• High Mechanical strength, Consist Of Intensive Plastic & Aluminum Cast.
• Water & Oil Proof Construction.
• Conduit Design that is convenient for wiring .
• Various Actuators for different applications.
• Optimize tail line design to improve performance in some switches.
|
|
 |
 |
SCHL5000 |
SCHL5391 |
|
|
 |
 |
SCLS171 |
SCLS191 |
|
|
 |
 |
SCSA001 |
SCSA031 |
|
|
 |
 |
SCTZ6001 |
SCTZ6002 |
|
|
 |
 |
SCTZ8104 |
SCTZ8108 |
|
|
 |
 |
SCTZ8122 |
SCTZ8166 |
|
|
 |
 |
SCWLCA12-2-Q |
SCWLCA22 |
|
|
 |
|
SCWLD |
|
Limit Switches |
Operation Frequency |
Life (Under Rated OT) |
|
Sr.No. |
Item code |
Operating Force |
Release Force |
Contact Type |
Mechenial Per Min. |
Electrical per min. |
Mechenial |
Electrical |
Ingress Protection |
1 |
SCHL5000 |
750g-cm |
100g-cm |
1NC+1NO, 2NC+2NO* |
120 |
30 |
10,000,000 |
500,000 |
IP65 |
2 |
SCHL5391 |
550g-cm |
100g-cm |
120 |
30 |
10,000,000 |
500,000 |
IP65 |
3 |
SCSA001 |
800g-cm |
400g-cm |
120 |
30 |
10,000,000 |
500,000 |
IP66 |
4 |
SCSA031 |
400g-cm |
100g-cm |
120 |
30 |
10,000,000 |
500,000 |
IP66 |
5 |
SCLS171 |
100g-cm |
40g-cm |
120 |
30 |
10,000,000 |
500,000 |
IP65 |
6 |
SCLS191 |
500g-cm |
100g-cm |
120 |
30 |
10,000,000 |
500,000 |
IP65 |
7 |
SCWLD |
2720g-cm |
910g-cm |
120 |
30 |
15,000,000 |
500,000 |
IP66 |
8 |
SCWLCA2-2 |
1360g-cm |
227g-cm |
120 |
30 |
10,000,000 |
500,000 |
IP66 |
9 |
SCWLCA12-2-Q |
1360g-cm |
227g-cm |
120 |
30 |
10,000,000 |
500,000 |
IP66 |
10 |
SCTZ6001 |
250g-cm |
114g-cm |
120 |
30 |
10,000,000 |
500,000 |
IP65 |
11 |
SCTZ6002 |
250g-cm |
114g-cm |
120 |
30 |
10,000,000 |
500,000 |
IP65 |
12 |
SCTZ8104 |
750g-cm |
100g-cm |
120 |
30 |
10,000,000 |
500,000 |
IP65 |
13 |
SCTZ8108 |
750g-cm |
100g-cm |
120 |
30 |
10,000,000 |
500,000 |
IP65 |
14 |
SCTZ8122 |
900g-cm |
150g-cm |
120 |
30 |
10,000,000 |
500,000 |
IP65 |
15 |
SCTZ8166 |
150g |
- |
120 |
30 |
10,000,000 |
500,000 |
IP65 |
Ratings ( For SCTZ8,SCSA,SCHL,SCLS) |
Rated Voltage |
Noninductive load |
Inductive load |
Resistance load |
Lamp Load |
Inductive Load |
Motor Load |
NC |
NO |
NC |
NO |
NC |
NO |
NC |
NO |
125 VAC |
5 |
1.5 |
0.7 |
3 |
2.0 |
1.0 |
250 VAC |
5 |
1 |
0.5 |
3 |
1.5 |
0.8 |
8 VDC |
5 |
3 |
3 |
5 |
3 |
14 VDC |
5 |
3 |
3 |
4 |
3 |
30 VDC |
5 |
3 |
3 |
4 |
3 |
125 VDC |
0.4 |
|
|
|
|
250 VDC |
0.2 |
|
|
|
|
Inrush Current |
N.C.:24A |
N.O.:12A |
N.C.:Below 24A |
N.O.: Below 12A |
Ratings (For SCWL) |
Rated Voltage |
Noninductive load |
Inductive load |
Resistance load |
Lamp Load |
Inductive Load |
Motor Load |
NC |
NO |
NC |
NO |
NC |
NO |
NC |
NO |
125 VAC |
10 |
3 |
1.5 |
10 |
5.0 |
2.0 |
250 VAC |
5 |
2 |
1 |
5 |
3.0 |
1.0 |
480 VAC |
3 |
1.5 |
0.8 |
3 |
1.5 |
0.8 |
600 VAC |
1 |
1 |
0.5 |
1.5 |
1.0 |
0.5 |
8 VDC |
10 |
6 |
3 |
10 |
6 |
14 VDC |
10 |
6 |
3 |
10 |
6 |
30 VDC |
6 |
4 |
3 |
6 |
4 |
125 VDC |
0.8 |
0.2 |
0.2 |
0.8 |
0.2 |
250 VDC |
0.4 |
0.1 |
0.1 |
0.4 |
0.1 |
Inrush Current |
N.C.:24A |
N.O.:12A |
N.C.:Below 24A |
N.O.: Below 12A |